Crack Detection

Novitech’s Micron ILI technology has industry leading MFL based crack detection capabilities.

  • Using both AMFL and CMFL with IDD sensors, cracks can be detected in both the axial and circumferential directions.
  • Can be detected in a single run or by combining separate runs.
  • Cracks as small as 0.500” (12.7mm) in length and 20% deep can be reliably detected.
  • Long Seam Hook Crack
  • Long Seam Lack of Fusion
  • Circumferential SCC
  • Axial SCC
  • Cracking in Gouges

Long Seam Hook Crack

Integrity Threat Solutions:

micron-v10
micron-v09
micron-v08
micron-v07
micron-v06

Long Seam Lack of Fusion

Integrity Threat Solutions:

micron-v10
micron-v09
micron-v08
micron-v07
micron-v06

Circumferential Stress Corrosion Cracking

Integrity Threat Solutions:

micron-v10
micron-v09
micron-v05
micron-v04
micron-v03

Axial Stress Corrosion Cracking

Integrity Threat Solutions:

micron-v10
micron-v09
micron-v08
micron-v07
micron-v06

Cracking in Gouges

Integrity Threat Solutions:

micron-v10
micron-v09
micron-v08
micron-v07
micron-v06

Integrity Threats

  • Metal Loss and Corrosion
  • Crack Detection
  • Deformations and Mechanical Damage
  • IMU/INS Mapping and Geohazards

Novitech News

  • PPIM2024 innovation award
  • ILI Detection and Measurement of Elevated Stresses at Crack Locations
  • Novitech Debut’s Their New 8” Micron ILI® Crack Detection Tools at PPIM2022
  • What sets Novitech Inc. apart from other ILI companies?
  • Novitech and Campos EPC Collaboration
  • 2021 SGA Engineering Innovation Awards
  • Novitech’s Version 10 Micron ILI Technology
  • Novitech’s Modular Micron ILI Technology
  • Novitech’s 16″ Micron CMFL Tool
  • Detection and Sizing of Circumferential SCC Interacting with Girth Welds Using Novitech’s Micron ILI Technology
  • Novitech and Xcel Energy Present 2nd Paper on CSCC
  • Novitech Launches its New 10″ Version 10 Tool
  • Novitech and Xcel Energy Present a Paper on CSCC
  • Novitech’s 10″ Micron CMFL Tool
  • Novitech’s 8″ Micron CMFL Tool
  • Novitech Detects Transverse Stress Corrosion Cracking
  • First 8″ CMFL Tool to Negotiate Five Back to Back 1.5D Bends
  • Novitech Launches New Dual Flux Micron ILI MFL Inspection Technology
  • Novitech Micron ILI Axial Pinhole Detection
  • Novitech Completes 165 mile Run
  • Novitech Introduces a New Launch Tube
  • Novitech Completes its Very First ILI Run

Tool Development and Analysis Center:
331 Cityview Blvd, Unit 1
Vaughan, Ontario
Canada L4H 3M3
Office:
Ron Thompson, President:
Phone: ( 647 )-527-7235
Guillermo Solano, P.Eng
Senior Director:
Phone: ( 416 )-580-8126
info@novitechinc.com

  • About

  • Modular Micron ILI Technology®

  • Research and Development

  • Services

  • Careers

  • News

Copyright © 2025 Novitech